You are viewing BMP records related to the Reducing Emissions When Taking Compressors Off-line: Lessons Learned from Natural Gas STAR publication.

BMP ID Short Title Text of BMP
5761 Keep off-line compressors pressurized, eliminating methane vents. Methane Recovery - Option 1: "Keep off-line compressors pressurized... [which]... eliminates methane vents."
5763 Keep off-line compressors pressurized, reduces fugitive methan losses by 0.95 Mcf/hr. Methane Recovery - Option 1: "Keep off-line compressors pressurized... [which]... Reduces fugitive methane losses by 0.95 Mcf/hr (68%)."
5760 Keep off-line compressors pressurized, requiring no facility modifications. Methane Recovery - Option 1: "Keep off-line compressors pressurized...[which]...Requires no facility modifications."
5762 Keep off-line compressors pressurized, seal leak higher by 0.30 Mcf/hr. Methane Recovery - Option 1: "Keep off-line compressors pressurized... [which]... Seal leak higher by 0.30 Mcf/hr."
5765 Keep pressurized and install a static seal with these following instructions. Methane Recovery - Option 3: "Keep pressurized and install a static seal â—† Automatic controller activates rod packing seal on shutdown and ...
5764 Route off-line compressor gas to fuel with the following options. Methane Recovery - Option 2: "Route off-line compressor gas to fuel â—† Connect blowdown vent to fuel gas system â—† Off-line compressor ...