BMP ID: |
6351 |
Title: |
Mitigate compressor noise by treating each significant noise source |
Text: |
"Noise from compressors can be mitigated by treating each significant noise source: gas turbines or engines, compressors, exhaust outlets and air inlets, and cooling and ventilation fans. Abatement may involve changing the blades on fans, which can change the frequency of sound emitted, thereby removing the annoying tones. Engine noise can be muffled using automotive-type mufflers, or by housing the engines in acoustically insulated structures. Also, the entire compressor can be housed in an acoustically insulated building." |
Source Publication Name: |
Oil and Gas Accountability Project, Best Practices |
Citation Section: |
Noise |
Citation Page: |
1 |
Supplemental Documents: |
See the Source Document for links to supplemental information
|
Usage Type: |
Recommended |
Timing: |
• Production / Operation / Maintenance
|
Oil / Gas Field: |
|
Surface Ownership: |
• Federal
• State
• Private
|
Mineral Ownership: |
• Federal
• State
• Private
|
Primary Contact: |
Earthworks 1612 K. St., NW, Suite 808 Washington, DC 20006 United States |
|
Alternate Contact: |
|
|
Categories: |
Noise
Community
Wildlife
|
Location: |
General / Federal |
Species: |
|
Vegetation Types: |
|
General Comments: |
|
Cost-Benefit Analysis: |
|
BMP Efficacy: |
|
Date Entered: |
2010-02-03 14:09 UTC |
Last Updated: |
2011-02-02 19:54 UTC |